APPLICATION
Power cables for power networks, underground and in cable ducting. Suitable for direct burial.
STANDARDS
BS 6622, IEC 60502-2, IEC/EN 60228
CHARACTERISTICS
Voltage Rating Uo/U (Um) 6.35/11 (12)kV
BS 6622 XLPE MDPE 6.35/11 (12)kV Cable
APPLICATION
Power cables for power networks, underground and in cable ducting. Suitable for direct burial.
CHARACTERISTICS
Voltage Rating Uo/U (Um) 6.35/11 (12)kV
Temperature Rating
Fixed: 0°C to +90°C
Temperature Index
0°C to +90°C
Minimum Bending Radius
12 x overall diameter
(10 x overall diameter where bends are positioned adjacent to a joint or terminations provided that the bending is carefully controlled by the use of a former)
CONSTRUCTION
Conductor: Class 2 stranded copper conductor
Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene)
Insulation: XLPE (Cross-Linked Polyethylene)
Insulation Screen: Semi-conductive XLPE (Cross-Linked Polyethylene)
Separator: Water blocking tape
Insulation Screen: Semi-conductive XLPE (Cross-Linked Polyethylene)
Metallic Screen: Individual copper wire screen
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride)
Armour: SWA (Steel Wire Armoured)
Sheath: MDPE (Medium Density Polyethylene)
Sheath Colour
Red Black
DIMENSIONS | ||||||||||||||||||||||
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm2 | NOMINAL DIAMETER mm | NOMINAL WEIGHT kg/km | |||||||||||||||||||
Under Armour | Over Armour | Overall | ||||||||||||||||||||
1 | 50 | 21.7 | 24.9 | 28.5 | 1200 | |||||||||||||||||
1 | 70 | 23 | 26.2 | 30 | 1500 | |||||||||||||||||
1 | 95 | 24.7 | 27.9 | 31.7 | 1600 | |||||||||||||||||
1 | 120 | 26.7 | 29.9 | 33.9 | 2100 | |||||||||||||||||
1 | 150 | 27.5 | 31.5 | 35.7 | 2500 | |||||||||||||||||
1 | 185 | 29.3 | 33.3 | 37.5 | 2900 | |||||||||||||||||
1 | 240 | 31.6 | 35.6 | 40 | 3600 | |||||||||||||||||
1 | 300 | 34.6 | 38.6 | 43 | 4300 | |||||||||||||||||
1 | 400 | 37 | 41 | 45.8 | 5200 | |||||||||||||||||
1 | 500 | 40.5 | 45.5 | 50.5 | 6500 | |||||||||||||||||
1 | 630 | 44.6 | 49.6 | 54.8 | 8000 | |||||||||||||||||
1 | 800 | 48.8 | 53.8 | 59.2 | 9850 | |||||||||||||||||
1 | 1000 | 53.5 | 58.5 | 64.3 | 12100 | |||||||||||||||||
3 | 35 | 41.6 | 46.6 | 51.6 | 4700 | |||||||||||||||||
3 | 50 | 44.4 | 49.4 | 54.6 | 5300 | |||||||||||||||||
3 | 70 | 48.1 | 53.1 | 58.5 | 6300 | |||||||||||||||||
3 | 95 | 52 | 57 | 62.6 | 7300 | |||||||||||||||||
3 | 120 | 55.6 | 60.6 | 66.6 | 8400 | |||||||||||||||||
3 | 150 | 58.6 | 63.6 | 69.8 | 9600 | |||||||||||||||||
3 | 185 | 62.7 | 67.7 | 74.1 | 11000 | |||||||||||||||||
3 | 240 | 68.1 | 74.4 | 81.2 | 14000 | |||||||||||||||||
3 | 300 | 73.5 | 79.8 | 87 | 16600 |
CONDUCTORS Class 2 Stranded Conductors for Single Core and Multi-Core Cables | |||||||||||||||||||||||||
NOMINAL CROSS SECTIONAL AREA mm2 | NOMINAL DIAMETER mm | MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC ohms/km | |||||||||||||||||||||||
Circular | Circular Compacted | Shaped | Annealed Copper Conductor | ||||||||||||||||||||||
Cu | Al | Cu | Al | Cu | Al | Plain Wires | |||||||||||||||||||
25 | 7 | 7 | 6 | 6 | 6 | 6 | 0.727 | ||||||||||||||||||
35 | 7 | 7 | 6 | 6 | 6 | 6 | 0.524 | ||||||||||||||||||
50 | 19 | 19 | 6 | 6 | 6 | 6 | 0.387 | ||||||||||||||||||
70 | 19 | 19 | 12 | 12 | 12 | 12 | 0.268 | ||||||||||||||||||
95 | 19 | 19 | 15 | 15 | 15 | 15 | 0.193 | ||||||||||||||||||
120 | 37 | 37 | 18 | 15 | 18 | 15 | 0.153 | ||||||||||||||||||
150 | 37 | 37 | 18 | 15 | 18 | 15 | 0.124 | ||||||||||||||||||
185 | 37 | 37 | 30 | 30 | 30 | 30 | 0.0991 | ||||||||||||||||||
240 | 37 | 37 | 34 | 30 | 34 | 30 | 0.0754 | ||||||||||||||||||
300 | 61 | 61 | 34 | 30 | 34 | 30 | 0.0601 | ||||||||||||||||||
400 | 61 | 61 | 53 | 53 | 53 | 53 | 0.047 | ||||||||||||||||||
500 | 61 | 61 | 53 | 53 | 53 | 53 | 0.0366 | ||||||||||||||||||
630 | 91 | 91 | 53 | 53 | 53 | 53 | 0.0283 | ||||||||||||||||||
800 | 91 | 91 | 53 | 53 | - | - | 0.0221 | ||||||||||||||||||
1000 | 91 | 91 | 53 | 53 | - | - | 0.0176 |
ELECTRICAL CHARACTERISTICS Current Carrying Capacity | |||||||||||||||||||||||||
NO. OF CORES | NOMINAL CROSS SECTIONAL AREA mm2 | CONTINUOUS CURRENT RATING Amps | |||||||||||||||||||||||
In Ground | In Ducts | In Air | |||||||||||||||||||||||
Trefoil | Flat | Trefoil | Flat | Trefoil | Flat | ||||||||||||||||||||
1 | 50 | 220 | 230 | 220 | 220 | 250 | 300 | ||||||||||||||||||
1 | 70 | 270 | 280 | 260 | 270 | 310 | 370 | ||||||||||||||||||
1 | 95 | 320 | 335 | 305 | 325 | 375 | 460 | ||||||||||||||||||
1 | 120 | 360 | 380 | 340 | 370 | 430 | 530 | ||||||||||||||||||
1 | 150 | 410 | 430 | 375 | 410 | 490 | 600 | ||||||||||||||||||
1 | 185 | 455 | 485 | 410 | 460 | 550 | 690 | ||||||||||||||||||
1 | 240 | 520 | 560 | 470 | 540 | 650 | 820 | ||||||||||||||||||
1 | 300 | 580 | 640 | 500 | 610 | 740 | 940 | ||||||||||||||||||
1 | 400 | 650 | 730 | 530 | 690 | 840 | 1100 | ||||||||||||||||||
1 | 500 | 710 | 830 | 570 | 780 | 930 | 1280 | ||||||||||||||||||
1 | 630 | 760 | 940 | 620 | 890 | 1040 | 1480 | ||||||||||||||||||
1 | 800 | 810 | 1060 | 660 | 990 | 1140 | 1690 | ||||||||||||||||||
1 | 1000 | 860 | 1170 | 690 | 1090 | 1230 | 1900 | ||||||||||||||||||
3 | 35 | 170 | 170 | 150 | 150 | 175 | 175 | ||||||||||||||||||
3 | 50 | 210 | 210 | 180 | 180 | 220 | 220 | ||||||||||||||||||
3 | 70 | 250 | 250 | 215 | 215 | 270 | 270 | ||||||||||||||||||
3 | 95 | 300 | 300 | 255 | 255 | 330 | 330 | ||||||||||||||||||
3 | 120 | 340 | 340 | 290 | 290 | 380 | 380 | ||||||||||||||||||
3 | 150 | 380 | 380 | 330 | 330 | 430 | 430 | ||||||||||||||||||
3 | 185 | 430 | 430 | 370 | 370 | 490 | 490 | ||||||||||||||||||
3 | 240 | 500 | 500 | 430 | 430 | 570 | 570 | ||||||||||||||||||
3 | 300 | 540 | 540 | 470 | 470 | 650 | 650 |