Voltage Rating Uo/U 0.6/1kV
Temperature Rating
Fixed: -30°C to +90°C
Minimum Bending Radius
During Installation: 15 x overall diameter Fixed: 10 x overall diameter
APPLICATION
These power cables are used for electricity supply in low voltage installation system. They are well adapted to
underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.
CHARACTERISTICS
Voltage Rating Uo/U 0.6/1kV
Temperature Rating
Fixed: -30°C to +90°C
Minimum Bending Radius
During Installation: 15 x overall diameter Fixed: 10 x overall diameter
CONSTRUCTION
Conductor: Up to 16mm2: Class 1 solid copper conductor Above 16mm2: Class 2 stranded copper conductor
Insulation: XLPE (Cross-Linked Polyethylene)
Sheath: LSZH (Low Smoke Zero Halogen)
STANDARDS
VDE0276 Part 604, IEC 60502-1, IEC/EN 60332-3-24 Cat.
C, IEC/EN 60228, EN 62230
In accordance with the installation standard IEC 60364 and as applicable to the equivalent National Codes for the rules for design, erection and verification of electrical installations, DIN VDE 0100, CEI 20-60, NEN 1010 and NF C15-100
NO. OF CONDUCTOR | NOMINAL CROSS SECTIONAL AREA mm2 | CONDUCTOR TYPE | NOMINAL OVERALL DIAMETER mm | NOMINAL WEIGHT kg/km | ||||||||||||||||
25 | RM | 9.9 | 132 | |||||||||||||||||
1 | 35 | RM | 11 | 166 | ||||||||||||||||
1 | 50 | RM | 12.5 | 211 | ||||||||||||||||
1 | 70 | RM | 14.1 | 283 | ||||||||||||||||
1 | 95 | RM | 16.1 | 376 | ||||||||||||||||
1 | 120 | RM | 17.5 | 456 | ||||||||||||||||
1 | 150 | RM | 19.6 | 560 | ||||||||||||||||
1 | 185 | RM | 21.8 | 697 | ||||||||||||||||
1 | 240 | RM | 24 | 878 | ||||||||||||||||
1 | 300 | RM | 26.7 | 1073 | ||||||||||||||||
1 | 400 | RM | 29.7 | 1347 | ||||||||||||||||
1 | 500 | RM | 33.1 | 1705 | ||||||||||||||||
3 | 16 | RM | 16.3 | 364 | ||||||||||||||||
3 | 25 | RM | 19.6 | 530 | ||||||||||||||||
3 | 35 | RM | 22.1 | 684 | ||||||||||||||||
3 | 35 | SE | 19 | 486 | ||||||||||||||||
3 | 50 | SM | 22.4 | 655 | ||||||||||||||||
3 | 50 | SE | 21.2 | 622 | ||||||||||||||||
3 | 70 | SM | 26.1 | 903 | ||||||||||||||||
3 | 70 | SE | 25.2 | 859 | ||||||||||||||||
3 | 95 | SM | 29.1 | 1174 | ||||||||||||||||
3 | 95 | SE | 27.8 | 1115 | ||||||||||||||||
3 | 120 | SM | 32.2 | 1446 | ||||||||||||||||
3 | 120 | SE | 30.8 | 1379 | ||||||||||||||||
3 | 150 | SM | 36.2 | 1780 | ||||||||||||||||
3 | 150 | SE | 33.9 | 1685 | ||||||||||||||||
3 | 185 | SM | 40.1 | 2197 | ||||||||||||||||
3 | 185 | SE | 37.6 | 2089 | ||||||||||||||||
3 | 240 | SM | 44.9 | 2782 | ||||||||||||||||
3 | 240 | SE | 41.8 | 2634 | ||||||||||||||||
3 | 70 + 35 | SM+SM | 28.3 | 1044 | ||||||||||||||||
3 | 120 + 70 | SM+SM | 35.1 | 1704 | ||||||||||||||||
3 | 150 + 70 | SM+SM | 39.7 | 2065 | ||||||||||||||||
3 | 185 + 95 | SM+SM | 43.7 | 2563 | ||||||||||||||||
3 | 240 + 120 | SM+SM | 49.1 | 3237 | ||||||||||||||||
4 | 25 | RM | 21.7 | 636 | ||||||||||||||||
4 | 35 | SM | 22.4 | 649 | ||||||||||||||||
4 | 35 | SE | 21.6 | 623 | ||||||||||||||||
4 | 50 | SM | 25.4 | 845 | ||||||||||||||||
4 | 50 | SE | 24.6 | 810 | ||||||||||||||||
4 | 70 | SM | 29.7 | 1178 | ||||||||||||||||
4 | 70 | SE | 28.8 | 1126 | ||||||||||||||||
4 | 95 | SM | 33.3 | 1538 | ||||||||||||||||
4 | 95 | SE | 32.1 | 1467 | ||||||||||||||||
4 | 120 | SM | 37.2 | 1903 | ||||||||||||||||
4 | 120 | SE | 35.5 | 1817 | ||||||||||||||||
4 | 150 | SM | 41.3 | 2328 | ||||||||||||||||
4 | 150 | SE | 39.4 | 2223 | ||||||||||||||||
4 | 185 | SM | 45.7 | 2874 | ||||||||||||||||
4 | 185 | SE | 43.4 | 2750 | ||||||||||||||||
4 | 240 | SM | 51.2 | 3646 | ||||||||||||||||
4 | 240 | SE | 48 | 3465 | ||||||||||||||||
5 | 25 | RM | 23.9 | 763 | ||||||||||||||||
5 | 35 | RM | 27 | 986 | ||||||||||||||||
5 | 50 | RM | 31.3 | 1309 | ||||||||||||||||
5 | 70 | RM | 35.8 | 1771 | ||||||||||||||||
5 | 95 | SM | 36.5 | 1891 | ||||||||||||||||
5 | 120 | SM | 39.2 | 2306 | ||||||||||||||||
5 | 150 | SM | 45.4 | 2865 | ||||||||||||||||
5 | 185 | SM | 50.1 | 3534 | ||||||||||||||||
5 | 240 | SM | 55.2 | 4482 |