NEWS
Contact Us
8618638668721
West Industrial Park, Zhulin Town, Gongyi City, Henan Province, China.

The Zimbabwe Tender We are Participating in for PVC Insulated Aluminium Overhead Service Cable

2024-07-03 14:49
Zimbabwe Tender PVC Insulated Aluminium Overhead Service Cable. we are participating in for Line Materials for ZETDC. The list of line items: Hard Drawn Aluminium Conductor; PVC/SWA Cables; Steel Reinforced Aluminium Conductor; PVC Insulated Aluminium Overhead Service Cable; Wire Galvanised Stay 7/8; Galvanised Stay Wire 7/12

PVC Insulated Aluminium Overhead Service Cable in Zimbabwe

25mm2 Aluminum Service Cable Construction

25mm2-aluminum-service-cable.jpg

Overhead Service Cable Parameter

Description Unit Required
Reference standards
IEC/BS
Insulator material
PVC/FR     UV
STABILISED
Conductor materia
Aluminium
Conductor size sq.
mm
25
Minimum insulation radial
thickness
mm 0.8
Minimum Averageinsulation
radial thickness
mm 0.92
Set Insulation     Radial
thickness
mm 0.97
No                      of
cores/Colour/Construction

2/BlackFig 8
Major    diameter over
insulation
mm 19
Minor    diameter over
insulation
mm 8.65
Method of installation
Air
Nominal Voltage V 400V  ph  to  ph
/230V ph to Neutral
System Highest Voltage V 440 V ph  to ph
250V ph to Neutral
System Frequency Hz 50
System Fault Leve kA 31.5
No.of inner cores ea two
Tensile    Strength of
Conductor material
N/mm2 125~165
Conductor construction Min No
ofwires
7/2.21
Conductor diameter mm 6.63
Conductor resistance at 20℃ ohm/k
m
1.066
Operating         ambient
temperature
1 to 40
Conductor       maximum
operating temperature
70
Maximum current carrying
capacity
A 92
Approximate       Voltage
Drop@power factor of 0.8
@50Hzand ambient air @
30 Deg Celcius
mV/A/
m
2.7
Spark test-A.C.(r.ms.)-10
kV

No breakdown
Voltage test-A.C.(r.ms.)-
2.0kV

No breakdown
Colour of sheath
Black
Insulation tensile Strength N/mm2 12.5
Insulation Elongation at
break

125%
Insulation resistance to
cracking
   Temp:150±2
Requirement:  No
   crack
Type of despatch drum ea Treatedwooden

AAC Cable Parameters

aac-cable.jpg

Hard Drawn Aluminum Wasp Conductor

Item Description Unit Requirement
1 Size mm2  100
2 CodeName
WASP
3 Overall Diameter    mm 13.17
4 Stranding
7/4.39
5 Uhtimate Tensile Strength kgf 1632
6 Mass per km Kg/km 290
7 (Maximum)AC Resistance at
20℃
ohms 0.27
8 Overall Area mm2 105.97

Hard Drawn Aluminum Ant Conductor

Item Description  Unit Requirement
1 Size   mm2  50
2 Code Name
Ant
3 Overall Diameter    mm 9.30
4 Stranding
7/3.10
5 Ultimate Tensile Strength   kgf 844
6 Mass per km    Kg/km 145
7 (Maximum)AC Resistance at
20℃
 ohms 0.54
8 Overall Area  mm² 52.83
9 Current Rating  Amps 244


Conductor Constants Aluminum Conductors Steel Reinforced



Requirement Requirement
1 Nominal Area Sq.mm 50 100
2 Code Name Rabbit Dog
3 Strands Alum. 6/3.35 6/4.02
4 No/diam mm Steel 1/3.35 7/1.57
5 Overall diam mm 10.05 14.15
6 Geom   Mean   Rad.Mm 2.5125 3.538
7 Overall area Sq.mm 61.71 118.40
8 Breaking Load kg 1,876  3,335 
9 moduhus oflnitial 6117 5765
10 Elasticity/Final 8085 7347
11 Coeff of linear expansion/deg.Cx 1/1000000 18.99 19.53




12 Mass kg/km


  Alum 144.62 260.53

  Steel 69.38 133.47

  Total 214.00 394.00




13 AC resistance ohms/km at 20 deg.C 0.556 0.306

Contact Us for Price List

Email:  info@qzcablegroup.com

WhatsApp/WeChat:  +8618638668721

WhatsApp

WhatsApp

WeChat

WeChat