Overview

Service Entrance Type SEU & SER

Service Entrance Cable Unarmored or U-shaped

Service Entrance Cable Round

 

Description

Service Entrance SEU: one or two XHHW-2 insulated conductors, paralleled, with concentric neutral, reinforced tape and PVC jacket. Service Entrance SER: two or three XHHW-2 insulated conductors, twisted together with or without bare grounding conductor, reinforced tape and PVC jacket.

Construction

Conductor Soft copper stranded and compressed. Insulation Cross Linked Polyethylene (XLPE 90°C).

Design

Service Entrance Type U, SEU: Round configuration for one phase conductor and neutral, flan configuration for two phase conductors and neutral.

Neutral

Service Entrance SEU : soft copper wires applied concentrically around phases with SZ technology (UL 854 Section 15.4)

Service Entrance SER: soft copper stranded, twisted together with phases

Binder

Tape Service Entrance SEU: polyester tape over neutral conductor Service Entrance SER: polyester tape over assembly

Jacket

Flame Retardant and Sunlight resistant PVC.

Options THWN-2 Conductors. Jacket with PVC LS (LOW Smoke emission).

Aluminum conductors.

Characteristics

Operating Temperature Dry and wet locations 90°C.

Operating Voltage 600 V.


Uses and Applications

Service Entrance or Drop Cable up to Service Entrance Equipment and to general breaker. May be used for branch circuits according to NEC and NTC 2050.

Standards and Specifications

Service Entrance Cables are manufactured under the following standards:

ASTM B3, NTC-359. Soft copper wires.

ASTM B8, NTC-307. Concentric Lay Stranded copper conductors. ASTM B787. 19 Wire Combination Unilay Stranded Copper conductors for subsequent insulation

UL 1581, NTC-3203. Reference Standard for Electrical Wires, Cables and Flexible Cords.

UL 854, NTC-ICONTEC 4564. Service Entrance Cables.

 


Service Entrance Type ARE & APE

A: Service Entrance R: Round Configuration E: Concentric Neutral Conductor

A: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor

 

Description

ARE: one or two XLPE insulated conductors, twisted together, with concentric

neutral, PVC filler and PE jacket.

APE: two XLPE insulated conductors, paralleled, with polyester tape, concentric

neutral, and PE jacket.

Service Entrance SER: two or three XHHW-2 insulated conductors, twisted

together with or without bare grounding conductor, reinforced tape and PVC

jacket.

Construction

Conductor: Soft copper stranded and compressed.

Insulation: Cross Linked Polyethylene (XLPE 90°C).

Configuration: ARE: Round. APE: Flat.

Binder Tape: APE: Polyester Tape over paralleled conductors.

Neutral: Soft copper wires applied concentrically around phases with SZ technology

with high coverage over phase conductors.

Jacket: Polyethylene (PE). Rip cord for easy installation.

Options: Aluminum conductor. PVC Insulation. Sunlight Resistant PVC Jacket.

Low Smoke Emission PVC Jacket.

Characteristics

Operation Temperature: Dry and wet locations 90°C.

Operating Voltage: 600 V.

Uses and Applications

Service Entrance or Drop Cable up to Service Entrance Equipment and to general breaker

Standards

ARE and APE Service Entrance Cables are manufactured under the following standards:

ASTM B3, NTC-359. Soft copper wires.

ASTM B8, NTC-307. Concentric Lay Stranded copper conductors.

Parameter

Service Entrance Type SEU 600V (International System Unit)

Service Entrance Cable Unarmored or U-shaped

 

Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables

CODE

SIZE AWG

STRANDS No.

STRANDING CLASS

CROSS SECTION

CONDUCTOR DIAMETER

INSULATION THICKNESS

DIAMETER OVER INSULATION

NEUTRAL SIZE AWG

NEUTRAL CONDUCTOR

POLYE STERICTAPE THICKNESS

JACKE TTHICKNESS

DIMENSIONS OVER JACKET

APPROX. TOTAL WEIGHT

DC RESISTANCE AT 20°C1

AMPACITY 2

(mm2)

(mm)

(mm)

(mm)

STRANDSNo.

STRANDDIAMETER(mm)

(mm)

(mm)

(mm)

(kg/km)

(ohm/km)

(A)

1 x 10 + 10

10

1

SOLID

5.26

2.59

0.76

4.18

10

26

0.51

0.032

0.76

6.82

126

3.28

40

1 x 8 + 8

8

7

B

8.37

3.59

1.14

5.96

8

41

0.51

0.032

1.14

9.36

216

2.1

55

1 x 6 + 6

6

7

B

13.3

4.52

1.14

6.89

6

41

0.64

0.032

1.14

10.56

316

1.32

75

1 x 4 + 4

4

7

B

21.15

5.71

1.14

8.08

4

41

0.81

0.032

1.14

12.08

475

0.831

95

1 x 2 + 2

2

7

B

33.63

7.2

1.14

9.57

2

41

1.02

0.032

1.14

13.99

721

0.523

130

2 x 10 + 10

10

1

SOLID

5.26

2.59

0.76

4.18

10

26

0.51

0.032

0.76

6.90 x 11.08

195

3.28

40

2 x 8 + 8

8

7

B

8.37

3.59

1.14

5.96

8

41

0.51

0.032

1.14

9.45 x 15.42

338

2.1

55

2 x 6 + 6

6

7

B

13.3

4.52

1.14

6.89

6

41

0.64

0.032

1.14

10.65 x 17.54

492

1.32

75

2 x 4 + 4

4

7

B

21.15

5.71

1.14

8.08

4

41

0.81

0.032

1.14

12.17 x 20.25

733

0.831

95

2 x 2 + 2

2

7

B

33.63

7.2

1.14

9.57

2

41

1.02

0.032

1.14

14.09 x 23.66

1107

0.523

130

2 x 8 + 10

8

7

B

8.37

3.59

1.14

5.96

10

26

0.51

0.032

1.14

9.45 x 15.42

309

2.1

55

2 x 6 + 8

6

7

B

13.3

4.52

1.14

6.89

8

41

0.51

0.032

1.14

10.38 x 17.28

445

1.32

75

2 x 4 + 6

4

7

B

21.15

5.71

1.14

8.08

6

41

0.64

0.032

1.14

11.83 x 19.91

657

0.831

95

2 x 2 + 4

2

7

B

33.63

7.2

1.14

9.57

4

41

0.81

0.032

1.14

13.66 x 23.23

989

0.523

130

 

Service Entrance Type SER 600V (International System Unit)

Service Entrance Cable Round

Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables

CODE

SIZE AWG

STRANDS No.

STRANDING CLASS

CROSS SECTION

CONDUCTOR DIAMETER

INSULATION THICKNESS

DIAMETER OVER INSULATION

NEUTRAL SIZE AWG

NEUTRAL CONDUCTOR STRANDS No.

NEUTRAL CONDUCTOR DIAMETER No.

ASSEMBLY DIAMETER

REINFOR CEDTAPE THICKNESS

JACKET THICKNESS

DIMENSIONS OVER JACKET

APPROX. TOTAL WEIGHT

DC RESISTANCE AT 20°C1

AMPACITY 2

(mm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(ohm/km)

(A)

3 x 8

8

7

B

8.37

3.59

1.14

5.96

-

-

-

12.85

0.1

0.76

14.75

344

2.12

55

3 x 6

6

7

B

13.3

4.52

1.14

6.89

-

-

-

14.86

0.1

0.76

16.75

501

1.34

75

3 x 4

4

7

B

21.15

5.71

1.14

8.08

-

-

-

17.41

0.1

0.76

19.3

744

0.84

95

3 x 2

2

7

B

33.63

7.2

1.14

9.57

-

-

-

20.62

0.1

0.76

22.52

1124

0.528

130

3 x 1

1

19

B

42.41

8.18

1.4

11.09

-

-

-

23.9

0.1

0.76

25.8

1411

0.419

150

3 x 1/0

1/0

19

B

53.48

9.18

1.4

12.09

-

-

-

26.05

0.1

0.76

27.95

1740

0.332

170

3 x 2/0

2/0

19

B

67.43

10.31

1.4

13.22

-

-

-

28.5

0.1

0.76

30.39

2153

0.263

195

3 x 3/0

3/0

19

B

85.03

11.58

1.4

14.49

-

-

-

31.23

0.1

0.76

33.13

2669

0.209

225

3 x 4/0

4/0

19

B

107.2

13

1.4

15.91

-

-

-

34.28

0.1

0.76

36.18

3317

0.166

260

3 x 8 + 8

8

7

B

8.37

3.59

1.14

5.96

8

7

3.59

13.72

0.1

0.76

15.61

424

2.12

55

3 x 6 + 6

6

7

B

13.3

4.52

1.14

6.89

6

7

4.52

15.86

0.1

0.76

17.75

626

1.34

75

3 x 4 + 6

4

7

B

21.15

5.71

1.14

8.08

6

7

4.52

18.58

0.1

0.76

20.47

870

0.84

95

3 x 2 + 4

2

7

B

33.63

7.2

1.14

9.57

4

7

5.71

22.01

0.1

0.76

23.91

1323

0.528

130

3 x 1/0 + 2

1/0

19

B

53.48

9.18

1.4

12.09

2

7

7.2

27.81

0.1

0.76

29.7

2055

0.332

170

3 x 2/0 + 1

2/0

19

B

67.43

10.31

1.4

13.22

1

19

8.18

30.41

0.1

0.76

32.31

2548

0.263

195

3 x 3/0 + 1/0

3/0

19

B

85.03

11.58

1.4

14.49

1/0

19

9.18

33.33

0.1

0.76

35.23

3167

0.209

225

3 x 4/0 + 2/0

4/0

19

B

107.2

13

1.4

15.91

2/0

19

10.31

36.59

0.1

0.76

38.49

3943

0.166

260

 

Service Entrance Type ARE 600V (International System Unit)

A: Service Entrance R: Round Configuration E: Concentric Neutral Conductor

Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy

CODE

SIZE AWG

STRANDS No.

STRANDING CLASS

CROSS SECTION

CONDUCTOR DIAMETER

INSULATION THICKNESS

DIAMETER OVER INSULATION

FILLER THICKNESS

DIAMETER
OVER
FILLER

NEUTRAL
SIZE
AWG

NEUTRAL CONDUCTOR

JACKET THICKNESS

DIMENSIONS OVER JACKET

APPROX. TOTAL WEIGHT

DC RESISTANCE AT 20°C1

AMPACITY 2

(mm2)

(mm)

(mm)

(mm)

(mm)

(mm)

STRANDS
No.

STRAND
DIAMETER
(mm)

(mm)

(mm)

(kg/km)

(ohm/km)

(A)

1 x 12 + 12

12

1

SOLID

3.31

2.05

0.76

3.65

-

3.65

12

17

0.51

1.14

7.04

88

5.21

30

1 x 10 + 10

10

1

SOLID

5.26

2.59

0.76

4.18

-

4.18

10

26

0.51

1.14

7.58

126

3.28

40

1 x 8 + 8

8

7

B

8.37

3.59

1.14

5.96

-

5.96

8

41

0.51

1.14

9.36

202

2.1

55

1 x 6 + 8

6

7

B

13.3

4.52

1.14

6.89

-

6.89

8

41

0.51

1.14

10.29

254

1.32

75

1 x 4 + 6

4

7

B

21.15

5.71

1.14

8.08

-

8.08

6

41

0.64

1.14

11.73

382

0.83

95

1 x 2 + 4

2

7

B

33.63

7.2

1.14

9.57

-

9.57

4

41

0.81

1.52

14.36

598

0.52

130

2 x 12 + 12

12

1

SOLID

3.31

2.05

0.76

3.65

0.5

8.3

12

26

0.51

1.14

7.04

173

5.21

30

2 x 10 + 10

10

1

SOLID

5.26

2.59

0.76

4.18

0.5

9.37

10

26

0.51

1.14

7.58

243

3.28

40

2 x 8 + 8

8

7

B

8.37

3.59

1.14

5.96

0.5

12.93

8

41

0.51

1.14

9.36

408

2.1

55

2 x 6 + 8

6

7

B

13.3

4.52

1.14

6.89

0.5

14.79

8

41

0.51

1.14

10.29

543

1.32

75

2 x 4 + 6

4

7

B

21.15

5.71

1.14

8.08

0.5

17.15

6

41

0.64

1.14

11.73

794

0.831

95

2 x 2 + 4

2

7

B

33.63

7.2

1.14

9.57

0.5

20.14

4

41

0.81

1.52

14.36

1200

0.523

130

 

Service Entrance Type APE 600V (International System Unit)

A: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor

Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.

Power Cables rated 2000 volts or less for the Distribution of Electrical Energy

CODE

SIZE AWG

STRANDS No.

STRANDING CLASS

CROSS SECTION

CONDUCTOR DIAMETER

INSULATION THICKNESS

DIAMETER OVER INSULATION

NEUTRAL SIZE AWG

NEUTRAL CONDUCTOR STRANDS No.

POLYESTERIC
TAPE
THICKNESS
(mm)

JACKET
THICKNESS
(mm)

DIMENSIONS
OVER
JACKET
(mm)

APPROX. TOTAL WEIGHT

DC RESISTANCE AT 20°C1

AMPACITY 2

(mm2)

(mm)

(mm)

(mm)

(kg/km)

(ohm/km)

(A)

2 x 10 + 10

10

1

SOLID

5.26

2.59

0.76

4.18

10

26

0.032

1.14

7.67 x 11.86

196

3.28

40

2 x 8 + 8

8

7

B

8.37

3.59

1.14

5.96

8

41

0.032

1.14

9.45 x 15.42

316

2.1

55

2 x 6 + 6

6

7

B

13.3

4.52

1.14

6.89

6

41

0.032

1.14

10.65 x 17.54

467

1.32

75

2 x 4 + 4

4

7

B

21.15

5.71

1.14

8.08

4

41

0.032

1.14

12.17 x 20.25

704

0.831

95

2 x 2 + 2

2

7

B

33.63

7.2

1.14

9.57

2

41

0.032

1.14

14.09 x 23.66

1072

0.523

130

2 x 8 + 10

8

7

B

8.37

3.59

1.14

5.96

10

26

0.032

1.14

9.45 x 15.42

288

2.1

55

2 x 6 + 8

6

7

B

13.3

4.52

1.14

6.89

8

41

0.032

1.14

10.38 x 17.28

420

1.32

75

2 x 4 + 6

4

7

B

21.15

5.71

1.14

8.08

6

41

0.032

1.14

11.83 x 19.91

628

0.831

95

2 x 2 + 4

2

7

B

33.63

7.2

1.14

9.57

4

41

0.032

1.14

13.66 x 23.23

955

0.523

130